pab-jc   J Chain Antiserum   品牌 Invivogen

J Chain Antiserum

货号: pab-jc      产品名称: J Chain Antiserum   品牌: Invivogen 规格: 100 μg 二周到货 生化试验

J Chain Antiserum
J chain antiserum can be used for the detection of polymeric IgA and pentameric IgM by Western blotting. J chain antiserum was prepared by injection of purified human J chain in rabbits. This anti-human antiserum cross-reacts with the mouse J chain and is reported to cross react with numerous other species.
Application: Western blotting
Working dilution: 1 in 1,000
Isotype: Rabbit IgG

10009172-100   JC-1 Mitochondrial Membrane Potential Assay Kit   品牌 Cayman

JC-1 Mitochondrial Membrane Potential Assay Kit

货号: 10009172-100      产品名称: JC-1 Mitochondrial Membrane Potential Assay Kit   品牌: Cayman 规格: 100 tests 3周

JC-1 Mitochondrial Membrane Potential Assay Kit
Cayman Chemical Item Number 10009172
Description
Mitochondrial membrane potential, Δψm, is an important parameter of mitochondrial function used as an indicator of cell health. JC-1 is a lipophilic, cationic dye that can selectively enter into mitochondria and reversibly change color from green to red as the membrane potential increases. In healthy cells with high mitochondrial Δψm, JC-1 spontaneously forms complexes known as J-aggregates with intense red fluorescence. On the other hand, in apoptotic or unhealthy cells with low Δψm, JC-1 remains in the monomeric form, which shows only green fluorescence. Cayman’s JC-1 Mitochondrial Membrane Potential Assay Kit provides all the necessary reagents, as well as complete instructions, for analysis of mitochondrial integrity in whole cells. The assay is applicable to flow cytometry, fluorescence microscopy, and 96-well plate formats.
Stability 6 months
Storage -20°C
Shipping Wet ice in continental US; may vary elsewhere

-20°C

ALX-620-053-M005   JC-1 . iodide   品牌 Alexis

JC-1 . iodide

货号: ALX-620-053-M005      产品名称: JC-1 . iodide   品牌: Alexis 规格: 5 mg 3周到货 生化实验

JC-1 . iodideFluorescent probe to test Pgp activityJC-1 is a very sensitive fluorescent probe to test Pgp activity. In acute myeloid leukemia (AML) samples JC-1 is capable of distinguishing between resistant, intermediate and sensitive groups, whereas rhodamine 123 only recognizes the resistant group. As in cell lines, the red emission band (597nm) of JC-1 appears to be more convenient for detection of low-level resistance in AML than other probes, such as rhodamine 123 (529nm) or calcein-AM (517nm). Green fluorescent JC-1 existing as a monomer ( Product SpecificationAlternative Name: 5,5′,6,6′-Tetrachloro-1,1′,3,3′-tetraethylbenzimidazolylcarbocyanine iodide Formula: C25H27Cl4IN4 MW: 652.2 CAS: 47729-63-5 Purity: ≥98% (HPLC) Appearance: Red solid. Solubility: Soluble in DMSO or methanol. Long Term Storage: +4°C Handling: Protect from light, especially when in solution. Keep cool and dry. +4°C

22200   现货|JC-1 [5,5,6,6-Tetrachloro-1,1,3,3-tetraethylbenzimidazolylcarbocyanine iodide]|线粒体膜电位荧光探针JC-1   品牌 AAT

现货|JC-1 [5,5,6,6-Tetrachloro-1,1,3,3-tetraethylbenzimidazolylcarbocyanine iodide]|线粒体膜电位荧光探针JC-1

货号: 22200      产品名称: 现货|JC-1 [5,5,6,6-Tetrachloro-1,1,3,3-tetraethylbenzimidazolylcarbocyanine iodide]|线粒体膜电位荧光探针JC-1   品牌: AAT 规格: 5 mg 现货

22201   JC-1 [5,5,6,6-Tetrachloro-1,1,3,3-tetraethylbenzimidazolylcarbocyanine iodide]   品牌 AAT

JC-1 [5,5,6,6-Tetrachloro-1,1,3,3-tetraethylbenzimidazolylcarbocyanine iodide]

货号: 22201      产品名称: JC-1 [5,5,6,6-Tetrachloro-1,1,3,3-tetraethylbenzimidazolylcarbocyanine iodide]   品牌: AAT 规格: 50 mg

22204   现货|JC-10 *Superior alternative to JC-1|线粒体膜电位荧光探针JC-10 *卓越的JC-1替代物*   品牌 AAT

现货|JC-10 *Superior alternative to JC-1|线粒体膜电位荧光探针JC-10 *卓越的JC-1替代物*

货号: 22204      产品名称: 现货|JC-10 *Superior alternative to JC-1|线粒体膜电位荧光探针JC-10 *卓越的JC-1替代物*   品牌: AAT 规格: 5×100 uL 现货

22800   Cell Meter JC-10 Mitochondrial Membrane Potential Assay Kit *Optimized for Microplate Assays*   品牌 AAT

Cell Meter JC-10 Mitochondrial Membrane Potential Assay Kit *Optimized for Microplate Assays*

货号: 22800      产品名称: Cell Meter JC-10 Mitochondrial Membrane Potential Assay Kit *Optimized for Microplate Assays*   品牌: AAT 规格: 1 kit 二周到货 生化试验

Cell Meter� JC-10 Mitochondrion Membrane Potential Assay Kit *Optimized for Microplate Assays*
Cat # 22800
Storage F/D/L (see storage codes below)
Unit Size 500 Tests
Ex (nm) 510
Em (nm) 525
Although JC-1 is widely used in many labs, its poor water solubility makes it hard to use for some applications. Even at 1 礛 concentration, JC-1 tends to precipitate in aqueous buffer. JC-10 has been developed to be a superior alternative to JC-1 where high dye concentration is desired. Compared to JC-1, our JC-10 has much better water solubility. JC-10 is capable of entering selectively into mitochondria, and changes reversibly its color from green to orange as membrane potentials increase. This property is due to the reversible formation of JC-10 aggregates upon membrane polarization that causes shifts in emitted light from 520 nm (i.e., emission of JC-10 monomeric form) to 570 nm (i.e., emission of J-aggregate). When excited at 490 nm, the color of JC-10 changes reversibly from green to greenish orange as the mitochondrial membrane becomes more polarized. This Cell Meter� JC-10 Mitochondrial Membrane Potential Assay Kit enable you to monitor mitochondrial membrane potential changes using a simple microplate reader while all the other commercial JC-1 assay kits require the use of a flow cytometer. Our kit provides the most robust method to monitor mitochondrial membrane potential changes, and can be readily used for screening a large compound library.
Detailed Information:   Protocol      References      MSDS      Spectrum
Related Products:     Cell Cytotoxicity     Apoptosis and Cytotoxicity     Cell Apoptosis 
Storage Codes:
  D = Desiccated
  L = Avoid light
  F = Freeze (<-15 癈)
  R = Refrigerated (2-4 癈)
  RT = Room temperature (4-50 癈)
 

22801   Cell Meter JC-10 Mitochondrial Membrane Potential Assay Kit *Optimized for Flow Cytometry Assays*   品牌 AAT

Cell Meter JC-10 Mitochondrial Membrane Potential Assay Kit *Optimized for Flow Cytometry Assays*

货号: 22801      产品名称: Cell Meter JC-10 Mitochondrial Membrane Potential Assay Kit *Optimized for Flow Cytometry Assays*   品牌: AAT 规格: 1 kit 二周到货 生化试验

Cell Meter� JC-10 Mitochondrion Membrane Potential Assay Kit *Optimized for Flow Cytometry Assays*
Cat # 22801
Storage F/D/L (see storage codes below)
Unit Size 100 Tests
Ex (nm) 510
Em (nm) 525 
Although JC-1 is widely used in many labs, its poor water solubility causes extraordinary inconvenience. Even at 1 礛 concentration, JC-1 tends to precipitate in aqueous buffer. JC-10 is developed to be a superior alternative to JC-1 where high dye concentration is desired. Compared to JC-1, JC-10 has much better water solubility. JC-10 is capable of entering selectively into mitochondria, and changes reversibly its color from green to orange as membrane potentials increase. This property is due to the reversible formation of JC-10 aggregates upon membrane polarization that causes shifts in emitted light from 520 nm (i.e., emission of JC-10 monomeric form) to 570 nm (i.e., emission of J-aggregate). When excited at 490 nm, the color of JC-10 changes reversibly from green to greenish orange as the mitochondrial membrane becomes more polarized. Both colors can be detected using the filters commonly mounted in all flow cytometers, so that green emission can be analyzed in fluorescence channel 1 (FL1) and greenish orange emission in channel 2 (FL2). Besides its potential use in flow cytometry, it can also be used in fluorescence imaging and fluorescence microplate platform. This kit provides all the essential components with an optimized assay method for the detection of apoptosis in cells with the loss of mitochondrial membrane potential. This fluorometric assay is based on the detection of the mitochondrial membrane potential changes in cells by the cationic, lipophilic JC-10 dye. In normal cells, JC-10 concentrates in the mitochondrial matrix where it forms red fluorescent aggregates. However, in apoptotic and necrotic cells, JC-10 exists in monomeric form and stains cells in green fluorescence. The kit is optimized for screening of apoptosis activators and inhibitors by flow cytometry. We also offer a convenient 96-well and 384-well fluorescence microtiter-plate format kit (cat#22800) for high through put screening. 
Detailed Information:   Protocol      References      MSDS      Spectrum
Related Products:     Cell Cytotoxicity     Apoptosis and Cytotoxicity     Cell Apoptosis 
Storage Codes:
  D = Desiccated
  L = Avoid light
  F = Freeze (<-15 癈)
  R = Refrigerated (2-4 癈)
  RT = Room temperature (4-50 癈)