1300   ReadiLink trFluor Eu Protein Labeling Kit *Microscale Optimized for Labeling 100 ug Antibody Per Reaction*   品牌 AAT

ReadiLink trFluor Eu Protein Labeling Kit *Microscale Optimized for Labeling 100 ug Antibody Per Reaction*

货号: 1300      产品名称: ReadiLink trFluor Eu Protein Labeling Kit *Microscale Optimized for Labeling 100 ug Antibody Per Reaction*   品牌: AAT 规格: 1 kit 二周到货 生化试验

ReadiLink� trFluor� Eu Antibody Labeling Kit *Microscale Optimized for Labeling 50 ug Antibody Per Reaction*
Cat # 1300
Storage F/D/L (see storage codes below)
Unit Size 2 Labelings
Ex (nm) 346
Em (nm) 617  
Solvent DMSO
Many biological compounds present in cells, serum or other biological fluids are naturally fluorescent, and thus the use of conventional, prompt fluorophores leads to serious limitations in assay sensitivity due to the high background caused by the autofluorescence of the biological molecules to be assayed. The use of long-lived fluorophores combined with time-resolved detection (a delay between excitation and emission detection) minimizes prompt fluorescence interferences. Our TR Fluor� Eu probes enable time-resolved fluorometry (TRF) for the assays that require high sensitivity. These TR Fluor� Eu probes have large Stokes shifts and extremely long emission half-lives when compared to more traditional fluorophores such as Alexa Fluor or cyanine dyes. Compared to the other TRF compounds, our TR Fluor� Eu probes have relatively high stability, high emission yield and ability to be linked to biomolecules. Moreover, our TR Fluor� Eu probes are insensitive to fluorescence quenching when conjugated to biological polymers such as antibodies.  
Detailed Information:   Protocol      References      MSDS      Spectrum
Related Products:     trFluor� Dyes and Kits 
Storage Codes:
  D = Desiccated
  L = Avoid light
  F = Freeze (<-15 癈)
  R = Refrigerated (2-4 癈)
  RT = Room temperature (4-50 癈)

 

1301   ReadiLink trFluor Eu Protein Labeling Kit *Production Scale Optimized for Labeling 10 mg Antibody Per Reaction*   品牌 AAT

ReadiLink trFluor Eu Protein Labeling Kit *Production Scale Optimized for Labeling 10 mg Antibody Per Reaction*

货号: 1301      产品名称: ReadiLink trFluor Eu Protein Labeling Kit *Production Scale Optimized for Labeling 10 mg Antibody Per Reaction*   品牌: AAT 规格: 1 kit

1302   ReadiLink trFluor Eu Protein Labeling Kit *Bulk Scale Optimized for Labeling 1 mg Antibody Per Reaction*   品牌 AAT

ReadiLink trFluor Eu Protein Labeling Kit *Bulk Scale Optimized for Labeling 1 mg Antibody Per Reaction*

货号: 1302      产品名称: ReadiLink trFluor Eu Protein Labeling Kit *Bulk Scale Optimized for Labeling 1 mg Antibody Per Reaction*   品牌: AAT 规格: 1 kit

1305   ReadiLink trFluor Tb Protein Labeling Kit *Microscale Optimized for Labeling 100 ug Antibody Per Reaction*   品牌 AAT

ReadiLink trFluor Tb Protein Labeling Kit *Microscale Optimized for Labeling 100 ug Antibody Per Reaction*

货号: 1305      产品名称: ReadiLink trFluor Tb Protein Labeling Kit *Microscale Optimized for Labeling 100 ug Antibody Per Reaction*   品牌: AAT 规格: 1 kit 二周到货 生化试验

ReadiLink� trFluor� Tb Protein Labeling Kit *Microscale Optimized for Labeling 50 ug Antibody Per Reaction*
Cat # 1305
Storage F/D/L (see storage codes below)
Unit Size 2 Labelings
Ex (nm) 330
Em (nm) 544 
Solvent DMSO
Many biological compounds present in cells, serum or other biological fluids are naturally fluorescent, and thus the use of conventional, prompt fluorophores leads to serious limitations in assay sensitivity due to the high background caused by the autofluorescence of the biological molecules to be assayed. The use of long-lived fluorophores combined with time-resolved detection (a delay between excitation and emission detection) minimizes prompt fluorescence interferences. Our TR Fluor� Tb probes enable time-resolved fluorometry (TRF) for the assays that require high sensitivity. These TR Fluor� Tb probes have large Stokes shifts and extremely long emission half-lives when compared to more traditional fluorophores such as Alexa Fluor or cyanine dyes. Compared to the other TRF compounds, our TR Fluor� Tb probes have relatively high stability, high emission yield and ability to be linked to biomolecules. Moreover, our TR Fluor� Tb probes are insensitive to fluorescence quenching when conjugated to biological polymers such as antibodies.  
Detailed Information:   Protocol      References      MSDS      Spectrum
Related Products:     trFluor� Dyes and Kits 
Storage Codes:
  D = Desiccated
  L = Avoid light
  F = Freeze (<-15 癈)
  R = Refrigerated (2-4 癈)
  RT = Room temperature (4-50 癈)

 

 

1306   ReadiLink trFluor Tb Protein Labeling Kit *Production Scale Optimized for Labeling 1 mg Antibody Per Reaction*   品牌 AAT

ReadiLink trFluor Tb Protein Labeling Kit *Production Scale Optimized for Labeling 1 mg Antibody Per Reaction*

货号: 1306      产品名称: ReadiLink trFluor Tb Protein Labeling Kit *Production Scale Optimized for Labeling 1 mg Antibody Per Reaction*   品牌: AAT 规格: 1 kit

1307   ReadiLink trFluor Tb Protein Labeling Kit *Bulk Scale Optimized for Labeling 10 mg Antibody Per Reaction*   品牌 AAT

ReadiLink trFluor Tb Protein Labeling Kit *Bulk Scale Optimized for Labeling 10 mg Antibody Per Reaction*

货号: 1307      产品名称: ReadiLink trFluor Tb Protein Labeling Kit *Bulk Scale Optimized for Labeling 10 mg Antibody Per Reaction*   品牌: AAT 规格: 1 kit

1433   trFluor Eu succinimidyl ester   品牌 AAT

trFluor Eu succinimidyl ester

货号: 1433      产品名称: trFluor Eu succinimidyl ester   品牌: AAT 规格: 1 mg 二周到货 生化试验

trFluor� Eu succinimidyl ester
Cat # 1433
Storage F/D/L (see storage codes below)
Unit Size 1 mg
Ex (nm) 346
Em (nm) 617
MW 1219.09
Solvent DMSO
Many biological compounds present in cells, serum or other biological fluids are naturally fluorescent, and thus the use of conventional, prompt fluorophores leads to serious limitations in assay sensitivity due to the high background caused by the autofluorescence of the biological molecules to be assayed. The use of long-lived fluorophores combined with time-resolved detection (a delay between excitation and emission detection) minimizes prompt fluorescence interferences. Our trFluor� Eu probes enable time-resolved fluorometry (TRF) for the assays that require high sensitivity. These trFluor� Eu probes have large Stokes shifts and extremely long emission half-lives when compared to more traditional fluorophores such as Alexa Fluor or cyanine dyes. Compared to the other TRF compounds, our trFluor� Eu probes have relatively high stability, high emission yield and ability to be linked to biomolecules. Moreover, our trFluor� Eu probes are insensitive to fluorescence quenching when conjugated to biological polymers such as antibodies.  
Detailed Information:   Protocol      References      MSDS      Spectrum
Related Products:     trFluor� Dyes and Kits     Labeling via Amino Groups 
Storage Codes:
  D = Desiccated
  L = Avoid light
  F = Freeze (<-15 癈)
  R = Refrigerated (2-4 癈)
  RT = Room temperature (4-50 癈)

 

1434   trFluor Eu maleimide   品牌 AAT

trFluor Eu maleimide

货号: 1434      产品名称: trFluor Eu maleimide   品牌: AAT 规格: 100 ug 二周到货 生化试验

trFluor� Eu maleimide
Cat # 1434
Storage F/D/L (see storage codes below)
Unit Size 100 ug
Ex (nm) 346
Em (nm) 617
MW 1169.96
Solvent DMSO
Many biological compounds present in cells, serum or other biological fluids are naturally fluorescent, and thus the use of conventional, prompt fluorophores leads to serious limitations in assay sensitivity due to the high background caused by the autofluorescence of the biological molecules to be assayed. The use of long-lived fluorophores combined with time-resolved detection (a delay between excitation and emission detection) minimizes prompt fluorescence interferences. Our trFluor� Eu probes enable time-resolved fluorometry (TRF) for the assays that require high sensitivity. These trFluor� Eu probes have large Stokes shifts and extremely long emission half-lives when compared to more traditional fluorophores such as Alexa Fluor or cyanine dyes. Compared to the other TRF compounds, our trFluor� Eu probes have relatively high stability, high emission yield and ability to be linked to biomolecules. Moreover, our trFluor� Eu probes are insensitive to fluorescence quenching when conjugated to biological polymers such as antibodies.  
Detailed Information:   Protocol      References      MSDS      Spectrum
Related Products:     trFluor� Dyes and Kits     Labeling via Thiol Groups 
Storage Codes:
  D = Desiccated
  L = Avoid light
  F = Freeze (<-15 癈)
  R = Refrigerated (2-4 癈)
  RT = Room temperature (4-50 癈)

 

1443   trFluor Tb succinimidyl ester   品牌 AAT

trFluor Tb succinimidyl ester

货号: 1443      产品名称: trFluor Tb succinimidyl ester   品牌: AAT 规格: 1 mg 二周到货 生化试验

trFluor� Tb succinimidyl ester
Cat # 1443
Storage F/D/L (see storage codes below)
Unit Size 1 mg
Ex (nm) 330
Em (nm) 544
MW 1226.05
Solvent DMSO
Many biological compounds present in cells, serum or other biological fluids are naturally fluorescent, and thus the use of conventional, prompt fluorophores leads to serious limitations in assay sensitivity due to the high background caused by the autofluorescence of the biological molecules to be assayed. The use of long-lived fluorophores combined with time-resolved detection (a delay between excitation and emission detection) minimizes prompt fluorescence interferences. Our trFluor� Tb probes enable time-resolved fluorometry (TRF) for the assays that require high sensitivity. These trFluor� Tb probes have large Stokes shifts and extremely long emission half-lives when compared to more traditional fluorophores such as Alexa Fluor or cyanine dyes. Compared to the other TRF compounds, our trFluor� Tb probes have relatively high stability, high emission yield and ability to be linked to biomolecules. Moreover, our trFluor� Tb probes are insensitive to fluorescence quenching when conjugated to biological polymers such as antibodies.  
Detailed Information:   Protocol      References      MSDS      Spectrum
Related Products:     trFluor� Dyes and Kits     Labeling via Amino Groups 
Storage Codes:
  D = Desiccated
  L = Avoid light
  F = Freeze (<-15 癈)
  R = Refrigerated (2-4 癈)
  RT = Room temperature (4-50 癈)

 

 

 

1444   trFluor Tb maleimide   品牌 AAT

trFluor Tb maleimide

货号: 1444      产品名称: trFluor Tb maleimide   品牌: AAT 规格: 100 ug 二周到货 生化试验

trFluor� Tb maleimide
Cat # 1444
Storage F/D/L (see storage codes below)
Unit Size 100 ug
Ex (nm) 330
Em (nm) 544
MW 1123.92
Solvent DMSO
Many biological compounds present in cells, serum or other biological fluids are naturally fluorescent, and thus the use of conventional, prompt fluorophores leads to serious limitations in assay sensitivity due to the high background caused by the autofluorescence of the biological molecules to be assayed. The use of long-lived fluorophores combined with time-resolved detection (a delay between excitation and emission detection) minimizes prompt fluorescence interferences. Our trFluor� Tb probes enable time-resolved fluorometry (TRF) for the assays that require high sensitivity. These trFluor� Tb probes have large Stokes shifts and extremely long emission half-lives when compared to more traditional fluorophores such as Alexa Fluor or cyanine dyes. Compared to the other TRF compounds, our trFluor� Tb probes have relatively high stability, high emission yield and ability to be linked to biomolecules. Moreover, our trFluor� Tb probes are insensitive to fluorescence quenching when conjugated to biological polymers such as antibodies.  
Detailed Information:   Protocol      References      MSDS      Spectrum
Related Products:     trFluor� Dyes and Kits     Labeling via Thiol Groups 
Storage Codes:
  D = Desiccated
  L = Avoid light
  F = Freeze (<-15 癈)
  R = Refrigerated (2-4 癈)
  RT = Room temperature (4-50 癈)

 

 

16518   trFluor Eu goat anti-mouse IgG (H+L)   品牌 AAT

trFluor Eu goat anti-mouse IgG (H+L)

货号: 16518      产品名称: trFluor Eu goat anti-mouse IgG (H+L)   品牌: AAT 规格: 100 ug 二周到货 生化试验

trFluor� Eu goat anti-mouse IgG (H+L)
Cat # 16518
Storage F/D/L (see storage codes below)
Unit Size 100 ug
Ex (nm) 346
Em (nm) 617 
Solvent Water
Many biological compounds present in cells, serum or other biological fluids are naturally fluorescent, and thus the use of conventional, prompt fluorophores leads to serious limitations in assay sensitivity due to the high background caused by the autofluorescence of the biological molecules to be assayed. The use of long-lived fluorophores combined with time-resolved detection (a delay between excitation and emission detection) minimizes prompt fluorescence interferences. Our trFluor� Eu probes enable time-resolved fluorometry (TRF) for the assays that require high sensitivity. trFluor� Eu probes have large Stokes shifts and extremely long emission half-lives when compared to more traditional fluorophores such as Alexa Fluor or cyanine dyes. Compared to the other TRF compounds, our trFluor� Eu probes have relatively high stability, high emission yield and ability to be linked to biomolecules. This trFluor� Eu goat anti-mouse IgG (H+L) conjugate is commonly used as a second step reagent for indirect immunofluorescent staining, when used in conjunction with biotinylated primary antibodies. It is a very valuable tool for biotin-streptavidin-based biological assays and tests using TR-FRET platform. 
Detailed Information:   Protocol      References      MSDS      Spectrum
Related Products:     Fluorescent Anti-IgGs     iFluor� Dyes and Kits     Tag Antibodies 
Storage Codes:
  D = Desiccated
  L = Avoid light
  F = Freeze (<-15 癈)
  R = Refrigerated (2-4 癈)
  RT = Room temperature (4-50 癈)

 

16519   trFluor Tb goat anti-mouse IgG (H+L)   品牌 AAT

trFluor Tb goat anti-mouse IgG (H+L)

货号: 16519      产品名称: trFluor Tb goat anti-mouse IgG (H+L)   品牌: AAT 规格: 100 ug 二周到货 生化试验

trFluor� Tb goat anti-mouse IgG (H+L)
Cat # 16519
Storage F/D/L (see storage codes below)
Unit Size 100 ug
Ex (nm) 330
Em (nm) 544  
Solvent Water
Many biological compounds present in cells, serum or other biological fluids are naturally fluorescent, and thus the use of conventional, prompt fluorophores leads to serious limitations in assay sensitivity due to the high background caused by the autofluorescence of the biological molecules to be assayed. The use of long-lived fluorophores combined with time-resolved detection (a delay between excitation and emission detection) minimizes prompt fluorescence interferences. Our trFluor� Eu probes enable time-resolved fluorometry (TRF) for the assays that require high sensitivity. trFluor� Eu probes have large Stokes shifts and extremely long emission half-lives when compared to more traditional fluorophores such as Alexa Fluor or cyanine dyes. Compared to the other TRF compounds, our trFluor� Eu probes have relatively high stability, high emission yield and ability to be linked to biomolecules. This trFluor� Eu goat anti-mouse IgG (H+L) conjugate is commonly used as a second step reagent for indirect immunofluorescent staining, when used in conjunction with biotinylated primary antibodies. It is a very valuable tool for biotin-streptavidin-based biological assays and tests using TR-FRET platform. 
Detailed Information:   Protocol      References      MSDS      Spectrum
Related Products:     Fluorescent Anti-IgGs     iFluor� Dyes and Kits     Tag Antibodies 
Storage Codes:
  D = Desiccated
  L = Avoid light
  F = Freeze (<-15 癈)
  R = Refrigerated (2-4 癈)
  RT = Room temperature (4-50 癈)

16598   trFluor Eu goat anti-mouse IgG (H+L) *Cross Adsorbed*   品牌 AAT

trFluor Eu goat anti-mouse IgG (H+L) *Cross Adsorbed*

货号: 16598      产品名称: trFluor Eu goat anti-mouse IgG (H+L) *Cross Adsorbed*   品牌: AAT 规格: 100 ug 二周到货 生化试验

trFluor� Eu goat anti-mouse IgG (H+L) *Cross Adsorbed*
Cat # 16598
Storage F/D/L (see storage codes below)
Unit Size 100 ug
Ex (nm) 346
Em (nm) 617  
Solvent Water
Many biological compounds present in cells, serum or other biological fluids are naturally fluorescent, and thus the use of conventional, prompt fluorophores leads to serious limitations in assay sensitivity due to the high background caused by the autofluorescence of the biological molecules to be assayed. The use of long-lived fluorophores combined with time-resolved detection (a delay between excitation and emission detection) minimizes prompt fluorescence interferences. Our trFluor� Eu probes enable time-resolved fluorometry (TRF) for the assays that require high sensitivity. trFluor� Eu probes have large Stokes shifts and extremely long emission half-lives when compared to more traditional fluorophores such as Alexa Fluor or cyanine dyes. Compared to the other TRF compounds, our trFluor� Eu probes have relatively high stability, high emission yield and ability to be linked to biomolecules. This trFluor� Eu goat anti-mouse IgG (H+L) conjugate is commonly used as a second step reagent for indirect immunofluorescent staining, when used in conjunction with biotinylated primary antibodies. It is a very valuable tool for biotin-streptavidin-based biological assays and tests using TR-FRET platform. 
Detailed Information:   Protocol      References      MSDS      Spectrum
Related Products:     Fluorescent Anti-IgGs     iFluor� Dyes and Kits     Tag Antibodies 
Storage Codes:
  D = Desiccated
  L = Avoid light
  F = Freeze (<-15 癈)
  R = Refrigerated (2-4 癈)
  RT = Room temperature (4-50 癈)

 

16599   trFluor Tb goat anti-mouse IgG (H+L) *Cross Adsorbed*   品牌 AAT

trFluor Tb goat anti-mouse IgG (H+L) *Cross Adsorbed*

货号: 16599      产品名称: trFluor Tb goat anti-mouse IgG (H+L) *Cross Adsorbed*   品牌: AAT 规格: 100 ug 二周到货 生化试验

trFluor� Tb goat anti-mouse IgG (H+L) *Cross Adsorbed*
Cat # 16599
Storage F/D/L (see storage codes below)
Unit Size 100 ug
Ex (nm) 330
Em (nm) 544 
Solvent Water
Many biological compounds present in cells, serum or other biological fluids are naturally fluorescent, and thus the use of conventional, prompt fluorophores leads to serious limitations in assay sensitivity due to the high background caused by the autofluorescence of the biological molecules to be assayed. The use of long-lived fluorophores combined with time-resolved detection (a delay between excitation and emission detection) minimizes prompt fluorescence interferences. Our trFluor� Eu probes enable time-resolved fluorometry (TRF) for the assays that require high sensitivity. trFluor� Eu probes have large Stokes shifts and extremely long emission half-lives when compared to more traditional fluorophores such as Alexa Fluor or cyanine dyes. Compared to the other TRF compounds, our trFluor� Eu probes have relatively high stability, high emission yield and ability to be linked to biomolecules. This trFluor� Eu goat anti-mouse IgG (H+L) conjugate is commonly used as a second step reagent for indirect immunofluorescent staining, when used in conjunction with biotinylated primary antibodies. It is a very valuable tool for biotin-streptavidin-based biological assays and tests using TR-FRET platform.
Detailed Information:   Protocol      References      MSDS      Spectrum
Related Products:     Fluorescent Anti-IgGs     iFluor� Dyes and Kits     Tag Antibodies 
Storage Codes:
  D = Desiccated
  L = Avoid light
  F = Freeze (<-15 癈)
  R = Refrigerated (2-4 癈)
  RT = Room temperature (4-50 癈)

 

 

 

16668   trFluor Eu goat anti-rabbit IgG (H+L)   品牌 AAT

trFluor Eu goat anti-rabbit IgG (H+L)

货号: 16668      产品名称: trFluor Eu goat anti-rabbit IgG (H+L)   品牌: AAT 规格: 100 ug 二周到货 生化试验

trFluor� Eu goat anti-rabbit IgG (H+L)
Cat # 16668
Storage F/D/L (see storage codes below)
Unit Size 100 ug
Ex (nm) 346
Em (nm) 617 
Solvent Water
Many biological compounds present in cells, serum or other biological fluids are naturally fluorescent, and thus the use of conventional, prompt fluorophores leads to serious limitations in assay sensitivity due to the high background caused by the autofluorescence of the biological molecules to be assayed. The use of long-lived fluorophores combined with time-resolved detection (a delay between excitation and emission detection) minimizes prompt fluorescence interferences. Our trFluor� Eu probes enable time-resolved fluorometry (TRF) for the assays that require high sensitivity. trFluor� Eu probes have large Stokes shifts and extremely long emission half-lives when compared to more traditional fluorophores such as Alexa Fluor or cyanine dyes. Compared to the other TRF compounds, our trFluor� Eu probes have relatively high stability, high emission yield and ability to be linked to biomolecules. This trFluor� Eu goat anti-rabbit IgG (H+L) conjugate is commonly used as a second step reagent for indirect immunofluorescent staining, when used in conjunction with biotinylated primary antibodies. It is a very valuable tool for biotin-streptavidin-based biological assays and tests using TR-FRET platform. 
Detailed Information:   Protocol      References      MSDS      Spectrum
Related Products:     Fluorescent Anti-IgGs     iFluor� Dyes and Kits     Tag Antibodies 
Storage Codes:
  D = Desiccated
  L = Avoid light
  F = Freeze (<-15 癈)
  R = Refrigerated (2-4 癈)
  RT = Room temperature (4-50 癈)

16669   trFluor Tb goat anti-rabbit IgG (H+L)   品牌 AAT

trFluor Tb goat anti-rabbit IgG (H+L)

货号: 16669      产品名称: trFluor Tb goat anti-rabbit IgG (H+L)   品牌: AAT 规格: 100 ug 二周到货 生化试验

trFluor� Tb goat anti-rabbit IgG (H+L)
Cat # 16669
Storage F/D/L (see storage codes below)
Unit Size 100 ug
Ex (nm) 330
Em (nm) 544  
Solvent Water
Many biological compounds present in cells, serum or other biological fluids are naturally fluorescent, and thus the use of conventional, prompt fluorophores leads to serious limitations in assay sensitivity due to the high background caused by the autofluorescence of the biological molecules to be assayed. The use of long-lived fluorophores combined with time-resolved detection (a delay between excitation and emission detection) minimizes prompt fluorescence interferences. Our trFluor� Eu probes enable time-resolved fluorometry (TRF) for the assays that require high sensitivity. trFluor� Eu probes have large Stokes shifts and extremely long emission half-lives when compared to more traditional fluorophores such as Alexa Fluor or cyanine dyes. Compared to the other TRF compounds, our trFluor� Eu probes have relatively high stability, high emission yield and ability to be linked to biomolecules. This trFluor� Eu goat anti-rabbit IgG (H+L) conjugate is commonly used as a second step reagent for indirect immunofluorescent staining, when used in conjunction with biotinylated primary antibodies. It is a very valuable tool for biotin-streptavidin-based biological assays and tests using TR-FRET platform. 
Detailed Information:   Protocol      References      MSDS      Spectrum
Related Products:     Fluorescent Anti-IgGs     iFluor� Dyes and Kits     Tag Antibodies 
Storage Codes:
  D = Desiccated
  L = Avoid light
  F = Freeze (<-15 癈)
  R = Refrigerated (2-4 癈)
  RT = Room temperature (4-50 癈)

16725   trFluor Eu goat anti-rabbit IgG (H+L) *Cross Absorbed*   品牌 AAT

trFluor Eu goat anti-rabbit IgG (H+L) *Cross Absorbed*

货号: 16725      产品名称: trFluor Eu goat anti-rabbit IgG (H+L) *Cross Absorbed*   品牌: AAT 规格: 100 ug 二周到货 生化试验

trFluor� Eu goat anti-rabbit IgG (H+L) *Cross Adsorbed*
Cat # 16725
Storage F/D/L (see storage codes below)
Unit Size 100 ug
Ex (nm) 346
Em (nm) 617  
Solvent Water
Many biological compounds present in cells, serum or other biological fluids are naturally fluorescent, and thus the use of conventional, prompt fluorophores leads to serious limitations in assay sensitivity due to the high background caused by the autofluorescence of the biological molecules to be assayed. The use of long-lived fluorophores combined with time-resolved detection (a delay between excitation and emission detection) minimizes prompt fluorescence interferences. Our trFluor� Eu probes enable time-resolved fluorometry (TRF) for the assays that require high sensitivity. trFluor� Eu probes have large Stokes shifts and extremely long emission half-lives when compared to more traditional fluorophores such as Alexa Fluor or cyanine dyes. Compared to the other TRF compounds, our trFluor� Eu probes have relatively high stability, high emission yield and ability to be linked to biomolecules. This trFluor� Eu goat anti-rabbit IgG (H+L) conjugate is commonly used as a second step reagent for indirect immunofluorescent staining, when used in conjunction with primary antibodies. 
Detailed Information:   Protocol      References      MSDS      Spectrum
Related Products:     Fluorescent Anti-IgGs     iFluor� Dyes and Kits     Tag Antibodies 
Storage Codes:
  D = Desiccated
  L = Avoid light
  F = Freeze (<-15 癈)
  R = Refrigerated (2-4 癈)
  RT = Room temperature (4-50 癈)

 

 

16726   trFluor Tb goat anti-rabbit IgG (H+L) *Cross Absorbed*   品牌 AAT

trFluor Tb goat anti-rabbit IgG (H+L) *Cross Absorbed*

货号: 16726      产品名称: trFluor Tb goat anti-rabbit IgG (H+L) *Cross Absorbed*   品牌: AAT 规格: 100 ug 二周到货 生化试验

trFluor� Tb goat anti-rabbit IgG (H+L) *Cross Adsorbed*
Cat # 16726
Storage F/D/L (see storage codes below)
Unit Size 100 ug
Ex (nm) 330
Em (nm) 544  
Solvent Water
Many biological compounds present in cells, serum or other biological fluids are naturally fluorescent, and thus the use of conventional, prompt fluorophores leads to serious limitations in assay sensitivity due to the high background caused by the autofluorescence of the biological molecules to be assayed. The use of long-lived fluorophores combined with time-resolved detection (a delay between excitation and emission detection) minimizes prompt fluorescence interferences. Our trFluor� Eu probes enable time-resolved fluorometry (TRF) for the assays that require high sensitivity. trFluor� Eu probes have large Stokes shifts and extremely long emission half-lives when compared to more traditional fluorophores such as Alexa Fluor or cyanine dyes. Compared to the other TRF compounds, our trFluor� Eu probes have relatively high stability, high emission yield and ability to be linked to biomolecules. This trFluor� Eu goat anti-rabbit IgG (H+L) conjugate is commonly used as a second step reagent for indirect immunofluorescent staining, when used in conjunction with primary antibodies.
Detailed Information:   Protocol      References      MSDS      Spectrum
Related Products:     Fluorescent Anti-IgGs     iFluor� Dyes and Kits     Tag Antibodies 
Storage Codes:
  D = Desiccated
  L = Avoid light
  F = Freeze (<-15 癈)
  R = Refrigerated (2-4 癈)
  RT = Room temperature (4-50 癈

16925   trFluor Eu-streptavidin conjugate   品牌 AAT

trFluor Eu-streptavidin conjugate

货号: 16925      产品名称: trFluor Eu-streptavidin conjugate   品牌: AAT 规格: 100 ug 二周到货 生化试验

trFluor� Eu-streptavidin conjugate
Cat # 16925
 Storage F/D/L (see storage codes below)
Unit Size 100 ug
Ex (nm) 346
Em (nm) 617  
Solvent Water
Streptavidin conjugates are widely used together with a conjugate of biotin for specific detection of a variety of proteins, protein motifs, nucleic acids and other molecules since streptavidin has a very high binding affinity for biotin. This trFluor� Eu-streptavidin conjugate comprises streptavidin (as the biotin-binding protein) with trFluor� Eu covalently attached (as the time-resolved red fluorescent europium label). It is commonly used as a second step reagent for indirect immunofluorescent staining, when used in conjunction with biotinylated primary antibodies. It is a very valuable tool for biotin-streptavidin-based biological assays and tests using TR-FRET platform. A variety of the complementary biotinylated reagents are available from numerous commercial vendors.  
Detailed Information:   Protocol      References      MSDS      Spectrum
Related Products:     Streptavidin Conjugates     trFluor� Dyes and Kits 
Storage Codes:
  D = Desiccated
  L = Avoid light
  F = Freeze (<-15 癈)
  R = Refrigerated (2-4 癈)
  RT = Room temperature (4-50 癈)

 

16926   trFluor Tb-streptavidin conjugate   品牌 AAT

trFluor Tb-streptavidin conjugate

货号: 16926      产品名称: trFluor Tb-streptavidin conjugate   品牌: AAT 规格: 100 ug 二周到货 生化试验

trFluor� Tb-streptavidin conjugate
Cat # 16926
Storage F/D/L (see storage codes below)
Unit Size 100 ug
Ex (nm) 330
Em (nm) 544  
Solvent Water
Streptavidin conjugates are widely used together with a conjugate of biotin for specific detection of a variety of proteins, protein motifs, nucleic acids and other molecules since streptavidin has a very high binding affinity for biotin. This trFluor� Tb-streptavidin conjugate comprises streptavidin (as the biotin-binding protein) with trFluor� Tb covalently attached (as the time-resolved green fluorescent terbium label). It is commonly used as a second step reagent for indirect immunofluorescent staining, when used in conjunction with biotinylated primary antibodies. It is a very valuable tool for biotin-streptavidin-based biological assays and tests using TR-FRET platform. A variety of the complementary biotinylated reagents are available from numerous commercial vendors.  
Detailed Information:   Protocol      References      MSDS      Spectrum
Related Products:     Streptavidin Conjugates     trFluor� Dyes and Kits 
Storage Codes:
  D = Desiccated
  L = Avoid light
  F = Freeze (<-15 癈)
  R = Refrigerated (2-4 癈)
  RT = Room temperature (4-50 癈)