22841   Cell Meter Fluorimetric Cell Cycle Assay Kit *Green Fluorescence Optimized for Flow Cytometry*   品牌 AAT

Cell Meter Fluorimetric Cell Cycle Assay Kit *Green Fluorescence Optimized for Flow Cytometry*

货号: 22841      产品名称: Cell Meter Fluorimetric Cell Cycle Assay Kit *Green Fluorescence Optimized for Flow Cytometry*   品牌: AAT 规格: 1 kit 二周到货 生化试验

Cell Meter� Fluorimetric Cell Cycle Assay Kit *Green Fluorescence Optimized for Flow Cytometry*
Cat # 22841
Storage F/D/L (see storage codes below)
Unit Size 1 kit
Ex (nm) 503
Em (nm) 526
Our Cell Meter� assay kits are a set of tools for monitoring cell viability and proliferation. There are a variety of parameters that can be used for monitoring cell viability and proliferation. In normal cells, DNA density changes depending on whether the cell is growing, dividing, resting, or performing its ordinary functions. The progression of the cell cycle is controlled by a complex interplay among various cell cycle regulators. These regulators activate transcription factors, which bind to DNA and turn on or off the production of proteins that result in cell division. Any misstep in this regulatory cascade causes abnormal cell proliferation which underlies many pathological conditions, such as tumor formation. Potential applications for live-cell studies are in the determination of cellular DNA content and cell cycle distribution for the detection of variations in growth patterns, for monitoring apoptosis, and for evaluating tumor cell behavior and suppressor gene mechanisms. This particular kit is designed to monitor cell cycle progression and proliferation using our proprietary Nuclear Green� CCS1 in live, permeabilized and fixed cells. The percentage of cells in a given sample that are in G0/G1, S and G2/M phases, as well as the cells in the sub-G1 phase prior to apoptosis can be determined by flow cytometry. Cells stained with Nuclear Green� CC1 can be monitored with a flow cytometer at Ex/Em = 490 nm/520 nm (FL1 channel). 
Detailed Information:   Protocol      References      MSDS      Spectrum
Related Products:     Cell Cytotoxicity     Apoptosis and Cytotoxicity     Cell Apoptosis 
Storage Codes:
  D = Desiccated
  L = Avoid light
  F = Freeze (<-15 癈)
  R = Refrigerated (2-4 癈)
  RT = Room temperature (4-50 癈)

 

22842   Cell Meter Fluorimetric Cell Cycle Assay Kit *Red Fluorescence Optimized for Flow Cytometry*   品牌 AAT

Cell Meter Fluorimetric Cell Cycle Assay Kit *Red Fluorescence Optimized for Flow Cytometry*

货号: 22842      产品名称: Cell Meter Fluorimetric Cell Cycle Assay Kit *Red Fluorescence Optimized for Flow Cytometry*   品牌: AAT 规格: 1 kit 二周到货 生化试验

Cell Meter� Fluorimetric Cell Cycle Assay Kit *Red Fluorescence Optimized for Flow Cytometry*
Cat # 22842
Storage F/D/L (see storage codes below)
Unit Size 1 kit
Ex (nm) 535
Em (nm) 617 
Our Cell Meter� assay kits are a set of tools for monitoring cell viability and proliferation. There are a variety of parameters that can be used for monitoring cell viability and proliferation. In normal cells, DNA density changes depending on whether the cell is growing, dividing, resting, or performing its ordinary functions. The progression of the cell cycle is controlled by a complex interplay among various cell cycle regulators. These regulators activate transcription factors, which bind to DNA and turn on or off the production of proteins that result in cell division. Any misstep in this regulatory cascade causes abnormal cell proliferation which underlies many pathological conditions, such as tumor formation. Potential applications for live-cell studies are in the determination of cellular DNA content and cell cycle distribution for the detection of variations in growth patterns, for monitoring apoptosis, and for evaluating tumor cell behavior and suppressor gene mechanisms. This particular kit is designed to monitor cell cycle progression and proliferation using Nuclear Red� CCS1, a cell cycle stain in fixed cells. The dye passes through a permeabilized membrane and intercalates into cellular DNA. The signal intensity of Nuclear Red� CCS1 is directly proportional to DNA content after RNA is degraded by RNase provided in the kit. The percentage of cells in a given sample that are in G0/G1, S and G2/M phases, as well as the cells in the sub-G1 phase prior to apoptosis can be monitored with a flow cytometer at Ex/Em = 490 nm/620 nm (FL2 channel).
Detailed Information:   Protocol      References      MSDS      Spectrum
Related Products:     Cell Cytotoxicity     Apoptosis and Cytotoxicity     Cell Apoptosis 
Storage Codes:
  D = Desiccated
  L = Avoid light
  F = Freeze (<-15 癈)
  R = Refrigerated (2-4 癈)
  RT = Room temperature (4-50 癈)
 

4461840   SOLID RUN CYCLE BUFFER KIT, DOUBLE   品牌 Invitrogen

SOLID RUN CYCLE BUFFER KIT, DOUBLE

货号: 4461840      产品名称: SOLID RUN CYCLE BUFFER KIT, DOUBLE   品牌: Invitrogen 规格: *** 三周到货 生化试验

SOLiD™ Run Cycle Buffer Kit, Double
SOLiD™ Buffers are used for ligation sequencing on the 5500⁄5500xl Genetic Analyzers. The SOLiD™ Run Cycle Buffer Kit (Double) contains a set of six buffers required during all types of sequencing runs for ligation sequencing in the forward and reverse directions. The kit consists of SOLiD™ Buffers A, B, C, E, F, and G.
SOLiD™ Buffers A, B, and E are provided in two parts, and components must be mixed before use. SOLiD™ Buffer F is provided as a 10X solution and requires dilution to 1X before pouring into its reagent tank. SOLiD™ Buffer G is poured into its reagent tank before use.
The kit contains sufficient reagents to run 950 to 1632 cycles, or up to 136 cycles per lane.
Form: Liquid 
Platform: 5500xl Genetic Analyzer,
5500 Genetic Analyzer 
Buffer Type: Sequencing Buffer 
Product Size: 1 kit 
Recommended Applications: Shotgun Sequencing,
De Novo Sequencing 
Regulatory Statement: For Research Use Only. Not for use in diagnostic procedures.
This kit contains buffers for two 5500⁄5500xl FlowChips.
Store SOLiD™ Buffers A and B at 2°C to 8°C until ready to mix and use. Store the SOLiD™ Buffer E kit at -25°C to -15°C until ready to mix and use. Store SOLiD™ Buffers C, F, and G at room temperature until ready to use.

4476801   KIT,5500W RUN CYCLE BUFFER KIT EACH   品牌 Invitrogen

KIT,5500W RUN CYCLE BUFFER KIT EACH

货号: 4476801      产品名称: KIT,5500W RUN CYCLE BUFFER KIT EACH   品牌: Invitrogen 规格: *** 三周到货 生化试验

5500 W Run Cycle Buffer Kit
5500 W buffers are used for ligation sequencing on the 5500 W Series genetic analyzers. The 5500 W Run Cycle Buffer Kit contains a set of six buffers required during all types of sequencing runs for ligation sequencing. The kit consists of 5500 W Buffers A, B, C, E, F, and G. The 5500 W Run Cycle Buffer Kit does not contain 5500 W Buffer D or 5500 W FWD Buffer.
5500 W Buffers A, B, and E are provided in two parts, and components must be mixed before use. 5500 W Buffer F is provided as a 10X solution and requires dilution to 1X before pouring into its reagent tank. 5500 W Buffer G is poured into its reagent tank before use.
Platform: 5500 Genetic Analyzer,
5500xl Genetic Analyzer
Buffer Type: Sequencing Buffer 
Product Size: 1 kit 
Regulatory Statement: For Research Use Only. Not for use in diagnostic procedures.
Store at -15 to -25 °C, 2 to 8 °C, and ambient

4414123   HUMAN CYCLINS AND CELL CYCLE   品牌 Invitrogen

HUMAN CYCLINS AND CELL CYCLE

货号: 4414123      产品名称: HUMAN CYCLINS AND CELL CYCLE   品牌: Invitrogen 规格: REGULATION KIT 三周到货 生化试验

TaqMan® Array Human Cyclins & Cell Cycle Regulation
These 96-well plates are pre-configured with the most appropriate TaqMan® Gene Expression Assays for a specific biological process, pathway, or disease state. Each plate contains predefined assays and endogenous controls dried-down in the wells, ready for accurate assessment of an entire gene signature in one simple experiment. The TaqMan® Array Human Cyclins And Cell Cycle Regulation 96-well Plate contains 44 assays to cyclins and cell cycle regulation associated genes and 4 assays to candidate endogenous control genes.
Form: Dried Down 
Format: 96-well plate 
Species: Human 
Label or Dye: FAM™ 
Product Size: 1 standard plate 
Reaction Speed: Standard 
Research Category: Signal Transduction,
Biomarker-Related Pathway(s),
Development,
Cell Cycle & Proliferation,
Neurobiology 
Internal Probe Modification: Non-Fluorescent Quencher (3′),
MGB (Minor Groove Binder) (3′),
FAM (5′)
Regulatory Statement: For Research Use Only. Not for use in diagnostic procedures.
Each TaqMan® Array Plate well contains a single TaqMan® Assay for one 20 µL reaction. The plates can be stored at room temperature or at 4°C.